34
3.2.6. PTZ
User can set detail for connecting PTZ camera to the DVR.
Check the below items for proper P/T/Z operation.
Check if the protocol of the connected PTZ camera is correct.
Check if the communication setting including baud rate of the connected PTZ camera is in
accordance with the assigned value for that P/T/Z protocol.
Check if the address of the connected PTZ camera is correct.
Check if wiring to P/T/Z controllers is correct.
Procedure
How to setup PTZ camera with Pelco-D protocol (example)
1) Make sure of serial communication with the PTZ camera through RS-485 port.
2) Select Pelco-D in the protocol list, and set address & baud rate.
3) Click Save button to confirm this configuration.
On
Select to use the connected PTZ camera.
ID
Set the ID of the PTZ camera.
Protocol
Select the proper protocol of the connected PTZ camera.
Baudrate
User can select the baud rate level from 2,400bps up to 115,200bps.
Databit
Select Databit in between DATA7 & DATA8.
Stopbit
Select Stopbit in between None & STOP1.
Parity
Select Parity among None, ODD & EVEN.